Home/Electrical-Engineering/Alternators

Alternators MCQs

172 questionsElectrical-EngineeringPage 17 of 20

Practice free Alternators multiple-choice questions with instant answer feedback and step-by-step solutions. Click an option to check yourself, reveal the full explanation, and work through all 172 questions — no login required.

Question 145easy
A 75 MVA, 10 kV synchronous generator has Xd = 0.4 p.u. The Xd value (in p.u.) to a base of 100 MVA, 11 kV is
Question 146easy
current with field excitation, at a given output power.
Question 147easy
A 50 Hz alternator is rated 500 MVA, 20 kV, with Xd = 1.0 per unit and X"d = 0.2 per unit. It supplies a purely resistive load of 400 MW at 20 kV. The load is connected directly across the generator terminals when a symmetrical fault occurs at the load terminals. The initial rms current in the generator in per unit is
Advertisement
Question 148easy
A power system has two synchronous generators. The Governor-turbine characterisitics corresponding to the generators are P1 =50 (50 -1), P2 = 100(51 -1) where f denotes the system frequency in Hz, and P1 and P2 are, respectively, the power outputs (in MW) of turbines 1 and 2. Assuming the generators and transmission network to be lossless, the system frequency for a total load of 400 MW is
Question 149easy
A stand alone engine driven Synchronous generator is feeding a partly inductive load. A capacitor is now connected across the load to completely nullify the nductive current. For this operating condition
Question 150easy
A capacitor is now connected across the load to completely nullify the nductive current.
Advertisement
Question 151easy
A round rotor generator with internal voltage E1 = 2.0 p.u. and X = 1.1 p.u. is connected to a round rotor synchronous motor with internal voltage E2 = 1.3 p.u. and X = 1.2 p.u. The reactance of the line connecting the generator to the motor is 0.5 p.u. When the generator supplies 0.5 p.u. power, the rotor angle difference between the machines will be
Question 152easy
Two 3-phase, Y-connected alternators are to be paralleled to a set of common busbars. The armature has a per phase synchronous reactance of 1.7SI and negligible armature resistance. The line voltage of the first machine is adjusted to 3300V and that of the second machine is adjusted to 3200V. The machine voltages are in phase at the instant they are paralleled. Under this condition, the synchronizing current per phase will be '
Question 153easy
A 400V, 50 kVA, 0.8 pf leading A-connected, 50 Hz synchronous machine has a synchronous reactance of 2S1 and negligible armature resistance. The friction and windage losses are 2 kW and the core loss is 0.8 kW. Teh shaft is supplying 9kW load at a power factor os 0.8 leading. The line current drawn is '